General specifications | |
---|---|
Passage speed | ? 12.5 m/s |
Measuring range | max. 314.5 m |
Free tolerances to code rail | horizontal: 31 mm ( ± 15.5 mm ) vertical: 28 mm ( ± 14 mm ) |
Resolution | ± 0.4 mm (1,250 positions/m) |
Functional safety related parameters | |
MTTFd | 50 a |
Mission Time (TM) | 10 a |
Diagnostic Coverage (DC) | 0 % |
Indicators/operating means | |
Operation indicator | LED green: power on |
Data flow indicator | LED yellow: data communication active |
Error indicator | LED red flashing: read head outside of code rail solid on: internal diagnostic test failed |
Display | Display module, 6-digit adaptable to installation position |
Electrical specifications | |
Operating voltage | 10 ... 30 V DC |
Power consumption | 2 VA |
Interface | |
Interface type | CANopen , galvanically isolated |
Data output code | binary code |
Transfer rate | max. 1 MBit/s |
Termination | switchable |
Standard conformity | |
Emitted interference | DINEN61000-6-4 |
Noise immunity | DINEN61000-6-2 |
Shock resistance | DIN EN 60068-2-27, half sine 30 g, 18 ms |
Vibration resistance | DIN EN 60068-2-6, sine, 5 g, 10 - 2000 Hz, 10 cycles |
Approvals and certificates | |
CSA approval | cCSAus Certified, General Purpose Class 2 power source |
CCC approval | CCC approval / marking not required for products rated ?36 V |
Ambient conditions | |
Operating temperature | 0 ... 60 °C (32 ... 140 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Relative humidity | 90 % , noncondensing |
Mechanical specifications | |
Connection type | 5-pin, M12 x 1 connector |
Degree of protection | IP54 |
Material | |
Mass | 500 g |
General information | |
Ordering information | Mounting plate included with delivery |
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
8 (017) 255-8-000 |