general data | |
---|---|
resolution | 640 × 480 px |
sensor type | 1/4" CCD, monochrome |
illumination | direct connection (integrated flash controller) |
illumination connection | as accessory |
high-resolution mode | max. 50 inspections per second |
high-speed mode (limited resolution) | max. 100 inspections per second |
number of jobs (products) | ≤ 255 |
features per job | 32 |
signal processing | Baumer FEX® 4.0 |
defect image memory | 32 |
lens | C-mount |
electrical data | |
voltage supply range +Vs | 18 … 30 V DC |
power consumption | typical 5 W (Imax = 1,5 A at 24 V) |
digital inputs | typical 5 W (Imax = 1,5 A at 24 V)5 inputs (8 … 30 V) trigger job selection external teach-in encoders (CH-A, CH-B) 500 kHz |
digital outputs | typical 5 W (Imax = 1,5 A at 24 V)5 inputs (8 … 30 V) trigger job selection external teach-in encoders (CH-A, CH-B) 500 kHz3 outputs (PNP) Pass / Fail Flash Sync Alarm Camera Ready Output Enable |
initial setup | Ethernet (10BASE-T / 100BASE-TX) |
process interface | Ethernet (10BASE-T / 100BASE-TX)TCP/UDP (Ethernet) RS485 |
visualization | web interface |
mechanical data | |
width | 53 mm (without lens/tube) |
height | 99,5 mm (without lens/tube) |
depth | 49,8 mm (without lens/tube) |
weight | ≤ 300 g (without lens/tube) |
material | ≤ 300 g (without lens/tube)housing: aluminum cover glass: PMMA |
environmental conditions | |
operating temperature | +5 … +50 °C |
storage temperature | -20 … +70 °C |
case temperature | max. +50 °C |
humidity | 0 … 90 % (non-condensing) |
protection class | IP 67 (with tube) |
vibration load | IP 67 (with tube)IEC 60068-2-6 IEC 60068-2-64 |
mechanical shock resistance | EN 60068-2-27 |
feature checks | |
part location | EN 60068-2-27part location on contours part location on edges part location on circle part location on text line |
geometry | EN 60068-2-27part location on contours part location on edges part location on circle part location on text linedistance circle angle count edges point position edge characteristics |
feature comparison | EN 60068-2-27part location on contours part location on edges part location on circle part location on text linedistance circle angle count edges point position edge characteristicscount contour points contour comparison brightness contrast area size count areas pattern comparison |
integrated flash controller | |
voltage | EN 60068-2-27part location on contours part location on edges part location on circle part location on text linedistance circle angle count edges point position edge characteristicscount contour points contour comparison brightness contrast area size count areas pattern comparison12 V DC or 24 V DC (permanent) 24 V DC or 48 V DC (pulsed) |
current | EN 60068-2-27part location on contours part location on edges part location on circle part location on text linedistance circle angle count edges point position edge characteristicscount contour points contour comparison brightness contrast area size count areas pattern comparison12 V DC or 24 V DC (permanent) 24 V DC or 48 V DC (pulsed)Imax = 800 mA at 24 V DC (permanent) (±10 %, at least ± 100 mA, at 25 °C) Imax = 4 A at 48 V DC (pulsed) (+10/-20 %, at least ± 100 mA, at 25 °C) |
flash time | max. 1 ms (Duty Cycle max. 1:10) |
conformity | |
conformity |